Mobile Diesel Fired Incinerator in container, supplied with the following specifications: complete with constant ventilation fans for extraction, factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. Fully containerised mobile waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner b. Dedicated independent fan system, damper controlled. c. Thermostatic Sensor d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor c. Minimum Temperature of 1100 deg.C as per WHO guidelines. d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play c. Threezone monitoring of: i)Primary chamber ii) Secondary chamber iii) Hot hearth d. Digital display e. Burner on-off indication lights f. Timer Chimney: a. Mild steel painted red b. Refractory insulated with 50mm of insulation. Unit Dimensions: 1840mm x 1 ‘1 50mm x 1950mm high. Safety: a. Burner door cut-off switches b. Fire valve fitted to fuel system c. Maximum noise at 1m x g0 decibels d. Exterior temperature 70 deg.C Max
1) Power Supply: ( a) Keys Supply: ( I) Singular Phase supply; 220– – 240V, 50Hz( ii) 3 Stage provide; 380– – 415V, 50Hz( iii) The power supply electrical outlet (sockets) for solitary stage supply system in the hospital is three pins as well as additionally adheres to BS1363. |} (b) Change:-LRB- I) Keys modification […]
a specific kind to make use of at a crematorium. Is this thing perfect, are ashes conveniently gathered and also so on a cremator, for pet facility, can you present and additionally all detail of earnings, tax responsibility, environtment.-Plastic. Glass containers as well as aluminum-. House waste-. Medical burner using a 10 kg/hour (15 lbs/hour) […]
dropped between 5000-10000 kg per hour.Mostly waste from petroleum storage tanks. Structure and construction, installation and also 6 months maintenance price including specifications.CMSD for Dual Chamber Rotating Klin Kind Incinerator (first Chamber temperatur not less than 850 degree centrigrade & & & & next Chamber Temperature Level not much less than 1200 c with exhaust […]
Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr. 2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste. 6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds. The incineration should be completely free from visible smoke as well as offensive odours. 9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter 11. The Volume of the combustion chamber: Not Less Than 2.3 M³ 12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel 14. The supplier must provide necessary information for the best of the installation
Sudan clinical waste burners layouts for clinical facilities of 100-300 bed in addition to 100-1000bed, kindly send out rate quote of all of the YD variations and also style of offer/ dispatch to nigeria heater is for use in the healthcare facility for shedding dangerous waste and likewise chimicals, minimal Capacity 300 per hr. The […]
a. 2.5 statistics tons daily health care waste burner b. 1.5 statistics stacks per day healthcare waste heater c. 300 kg per day medical care waste heater Our recommended technology is double-chamber incineration, but if you advocate a different modern-day technology, that is acceptable. We request information on the adhering to for each of the […]
Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg Loading Manual, Batch Load De Ashing Automatic or Manual batch de ashing The incinerator must avoid the release of black smoke and fine dust during the loading Primary chamber capacity […]
Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr. 2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste. 6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds. The incineration should be completely free from visible smoke as well as offensive odours. 9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter 11. The Volume of the combustion chamber: Not Less Than 2.3 M³ 12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel 14. The supplier must provide necessary information for the best of the installation
Double Combustion Chamber Containerized Mobile Incinerator All waste burner design with dual burning chamber. Heat, Smoke Remedy , No black smoke, Environment-friendly. Family Pet Dog&Cat Cremation The burner mounted in ISO Container prior to leave factory, free-installation, no incineration house develop construction and building, movable by truck. Installation and Commissioning Unique style with movable platform, […]