incinerator. High Temperature Waste Incinerator Model D. MB 750XL Burn Rate-150Kg/hour minimal Weight(Kg)-4000kg Secondary Chamber (double room with post-burning) Gas Retention Time 2 minute Fuel Diesel Power Supply for control box 220V-240, single phase 50-60Hz Minimum operating temperature 1200 oC 1 year spare parts package for complete maintainability 10m hose pipe. 1100 litre gas Tank […]
Smallest waste incinerator for small hospital average 10kgs per hour. with double(2) sets burner. Equipment Technical Specifications Model YD-10 Feed Capacity Typical 20 kgs per feed Burning Rate Typical 10 kgs Each hour Burning Time Each Feed 2 hours Voltage 220V Fuel Diesel Petroleum Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) 5.4-12.6 Kgs/Hour […]
the small scale medical incinerator for small waste out put capacity department. we have different model small scale medical incinerator which model is TS mode, YD model and also YDC model. the capacity from 10kgs per hour to 100kgs per hour. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour […]
HICLOVER Incinerator/Parts Range Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Ranked for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other creature incineration Temperature Control, Primary and Secondary Stoking tools Stainless Steel Spark Screen Primary Chamber Door Locking System HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification. 1. Medical Waste Incinerator(Containerized […]
Model A1500 Picture Brand/Product Code HICLOVER/N1134 Burning Rate Typical 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Organic Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Typical 34 kg/hour […]
Youth battle a waste incinerator. It is the threat of dangerous air pollution that has pupils at Curtis Bay’s Benjamin Franklin High School leaving the classroom and showing in the streets of Baltimore. In Curtis Bay, a neglected waterfront neighborhood in the northwestern fringes of Baltimore, an alliance of environmental activists and local groups–such as […]
Items/Model HICLOVER TS150(PLC) (Mobile Sort ) N1155 Picture mobile incinerator Principle Waste Incineration Remedy,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Electricity 0.9Kw Oil Infection (kg/hour) average 20.4 Gas Consumption […]
medical waste furnace also called medical waste incinerator. we use italy made burner for furnace and all the furnace design with two or three combustion chamber. the chimney for furnace is stainless steel for long life time. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. ) Operational Specs Physical Specs Combustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption […]
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.) Operational Specs Physical SpecsCombustion Chamber Volume (m3) 8.80m3 Burn Rate* up to 1,500kg per hour Average Fuel Consumption 65 kg per hour or more (7 diesel burners) Operational Temperature 850 – 1320°C Gas Retention in Secondary Chamber Large secondary chamber Temperature Monitoring Yes Average ash residue (%) 3% Thermostatic Device Yes 1000l diesel flue tankVenture gas scrubberHydraulic Ram Feeding SystemDiesel Powered Large Incinerator Minimum Specification Required Standards1) Bidder or Manufacturer ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line conditions.5) Compliance with applicable Ghanaian standards and regulations.Operational characteristics6) Two-stage incineration with dual chamber combustion7) Burn rate: 15 – 20 Kg/h8) Capacity: not less than 130 L9) Concentrations of most pollutants in stack gases below detection limits10) Diesel fuel11) Electronic system control12) Easy to operate and minimal training13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION