1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be managed, stored strictly and burnt by a incinerator located at hospital website. 2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows; Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Suggestion Price Cheap High cost Manufacture Tech. Easy A clutter tough Safty safe a lot more secure Burner Creating L/ I L Filling up hands-on huge door can be by Forklift Land project little big Ash door exact […]
The incinerator shall be equipped with water injection nozzle link. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800? C) during the working time, the automated water injection shall be actuated to decease the temperature. The incinerator shall have the following features and facilities:- a- […]
The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork will consist of refractory lined tubes and higher temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length. The standard chimney shall be made […]
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine dust, during the loadings. It shall have the ability to reduce the quantity of wastes by 98%. It shall have the ability to hold emission in the second burn with gas residence of not less […]
The incinerator to be completely assembled logic and wired function tested in the factory, before dispatch. – One high flue gas temperature indicator/alarm to provide an audio/visual warning in case of high flue gas temperatures occurring in two phases:- First stage audible alarm, second stage incinerator shutdown, with a single voltage free contact […]
* Burner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A regulator with electronic viewing for the temperature of combustion. 23. The installed incinerator must bear a one year guarantee. 22. Process Filtering system: Scruber to […]
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. HICLOVER Incinerator supply updated models with dual combustion chamber, mix-combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Tools Technical Specifications Version YD-10C Image Feed Capability Common 40 kgs […]
Incinerator Model A1500, Intro Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for […]
Animal Crematory Burner Ability: Regular 80kgs per feeding Thing Spec Design A900 Interior Measurements 120 x 90 x 85 CM Match for Family Pet Feline – – – – yes – Family pet – yes Pig – – small Cow – – no Key Product Checklist Key Burning Chamber Additional Burning Chamber Mix-Combustion Chamber Smoke […]
This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil/gas burner. Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary combustion chambers and included mix-combustion chamber. Waste load on the bottom of chamber. Incinerator panel control suit for local operation. Design YD-50 with […]
include automatic stop/start programmed timer control, flame failure gear and ignition failure gear to close off the fuel supply in case of malfunction. The burners shall be mounted so that waste can’t block the fire ports. — Blood bags & tubing, gloves, Gowns, curtains, etc.. — Contaminated packaging: bandage etc Each burner shall be designed […]
Oil tank with 2000Liters capacity Items/Model TS150( PLC) Image Principle Waste Incineration Therapy Burn Rate Requirement 100-150 kg/hour Feed Ability Standard 750kg/feeding Control Setting PLC( Programmable Thinking Controller Burner) Text Steel 8mm thickness Chamber Product High Alumina Fire Brick Wall Surface, 1750 ℃ Rate Paint for outside face 800 ° C Rate Combustion Chamber 1570L […]
The incinerator plant will incorporate a control panel for its own operation. On the control panel we will have a visual display of the room temperatures. This visual display must control and monitor the incinerator and his performance. Ability of destruction in weight will be 60 Kg/h. It should be able to operate not less […]
(adsbygoogle = window.adsbygoogle || []).push({}); Incinerator Variation CA100, Summary combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke filter chamber with firebrick and refractory concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for local […]