A single Ebola patient treated in a U.S. hospital will generate eight 55-gallon barrels of medical waste each day. Protective gloves, gowns, masks and booties are donned and doffed by all who approach the patient’s bedside and then discarded. Disposable medical instruments, packaging, bed linens, cups, plates, tissues, towels, pillowcases and anything that is used […]
  Containerized Mobile Incinerator with buring rate from 10kgs per hour and 20/30/50kgs per hour capacity. We fixed incinerator system inside the container already, local customer fix the electric system and smoke chimney. This product is moveable by truck to other location. All system completed with diesel oil fired. Completed with Double combustion chamber. Fixed […]
Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass typeConstruction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalentInsulation Refractory material liningCombustion Temperatures        Above 850 0C, controlled electronicallyGas residue or retention Time       > 2 second at minimum 850 0CSecondary Burner                    Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                  & nbsp;                                               Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type.                                                                  Flange mountedEjector Provided, Venturi type, for cooling the flue gasesCombustion Air Fan Provided for supplying combustion and creating a negative drift and turbulencesTemperature Maximum  1600 0C
Basic Info. Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm […]
Medical Waste Removal Companies Medical Waste Service Suggestions There are different types of wastes that people need to be conscious about in order to avoid exposure to this waste that may cause health illnesses and diseases. One of the most dangerous types of waste that people need to get rid of is hazardous wastes. These […]
Patients with this debilitating virus produce 440 gallons of medical waste daily, including instruments, gowns, gloves, body fluids, sheets, mattresses and more. That’s a substantial amount of medical waste in any situation, but it’s especially daunting in this case because it needs to be disposed of extremely cautiously, to avoid the risk of spreading infection. […]
Medical Waste Incinerator, 50 to 60 Kg/hrSupport Health Sector Support ProjectPoint of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals1.    General DescriptionSupply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment.  The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006).  The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual.  The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour.  It shall be constructed from mild or aluminized steel lined with refractory material.Main unit Application For incineration, general and pathologicalCapacity   50 C 60 kg/h burn rateType Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unitOperating time                Minimum 8 hours dailyOperating temperature     From 850 0C to 1200 0C, Automatic controlledResidual Ash                    5 to 10%    3.2     Primary ChamberConstruction Constructed from heavy duty mild or aluminized  steel Orequal and approved equivalentInsulation material            Refractory material lining similar or equal to calcium Silicate and hot face combination of heavy duty brickworkInternal Construction        Fixed hearth type complete with gratings, concave bottomand charging door, lined with refractory materialCharging Door                   Suitable for manual loading of wastes and with smooth Dear seal equivalent of Ceramic seals with hinges.Door Lock                          Automatic, Electric typeAsh removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamberGratings   ProvidedLoading Manual loading of wastePrimary Burner                        Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted                                                                                                    Blower Provided. For supplying excess combustion air through the distribution system with speed control systemTemperature Minimum exit 850 0CObservation port To be provided with protective glass typeConstruction   Constructed from heavy duty mild or aluminized steel or equal and approved equivalentInsulation Refractory material liningCombustion Temperatures        Above 850 0C, controlled electronicallyGas residue or retention Time       > 2 second at minimum 850 0CSecondary Burner                    Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                  & nbsp;                                               Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type.                                                                  Flange mountedEjector Provided, Venturi type, for cooling the flue gasesCombustion Air Fan Provided for supplying combustion and creating a negative drift and turbulencesTemperature Maximum  1600 0C
Basic Info. Model NO.:10 kg per hour Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Items/Model TS10(PLC) Burn Rate 10 kg/hour Feed Capacity 20kg Control Mode PLC Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) […]