Day: May 3, 2021

The incinerator to be fully assembled wired and logic function tested in the factory, prior to dispatch.   –      One high flue gas temperature indicator/alarm to provide an audio/visual warning in the event of high flue gas temperatures occurring in two stages:-   First stage audible alarm, second stage incinerator shutdown, with one voltage free […]
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence of not less than 2 […]
The incinerator shall be provided with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork shall consist of refractory lined tubes and high temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length.   The standard chimney shall be made […]
The incinerator shall be equipped with water injection nozzle connection. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800?C) during the operating time, the automatic water injection shall be activated to decease the temperature.   The incinerator shall have the following features and facilities:-   a-    Fuel […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Suggestion Cost Affordable High expense Manufacture Tech. Easy A clutter tough Safty safe a lot more protected Burner Creating L/ I L Filling up hands-on huge door can be by Forklift Land job little big Ash door exact […]
1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]
30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Idea Waste Incineration Burn Rate Criterion 30kgs/hour Gas Kind Diesel Oil/Natural […]